Assembly

kdh_stanz_mon_1
Establish and mark cut-outs.

Caution:
Ensure sufficient distance between the press cuts!

Mark drilling point for the pilot hole for the tension screw and punch out the pilot hole for the tension screw.
kdh_stanz_mon_2
Screw in corresponding tension screw into the tool head and close the valve on the punching tool. Push on appropriate spacer and die.
kdh_stanz_mon_3
Insert tension screw into pilot hole. Stick or screw stamp onto tension bolt. Secure with lock nut where needed. Align die and draw in lock nut by hand.
kdh_stanz_mon_4
Activate hydraulic mechanism until the press cut is completed. Then actuate 3 – 4 further strokes. This ensures an easier removal of the plate from the die. Caution: If excessive force is required, inspect the hydraulic tool and punching tool! Observe the tool's operating instructions.
kdh_stanz_mon_5
Remove hydraulic tool from the cut-out. Open valve and remove lock nut and stamp. Remove plate from the die.