Displaying Metric Units

Strain relief / cable fixing plate

Strain relief options in various variations and models. To screw on, snap in or press on. In plastic or metal. Cable ties are used to provide simple strain relief to cables of all kinds.


Strain relief, type ZL-fix

The strain relief ZL-fix may be used wherever cables, hoses, cords, wires or conduits must be relieved or routed in a way that is secure, easy and cost-effective. The strain relief ZL-fix is available in two versions, either for direct screw fastening (flat-head screw M5, not included in delivery) or for fastening on a profile with 10 mm groove width (integrated nut strap). Do not constrict sensitive cables such as fibre optic cables or pneumatic hoses Velcro fastening can be opened and closed infinitely without the need for tools Easiest handling Variable installation position


Strain relief, type ZL

The strain relief plate ZL may be used wherever cables, hoses, cords, wires or conduits must be relieved or routed in a way that is secure, easy and cost-effective. The insertion of the ELB bush stops the cold extrusion characteristic of plastic from affecting the secure fixing of the plate. The DH spacer sleeve is needed for two-tier mounting.


Strain relief, type ZL-AH / ZL-MH

The strain relief plates ZL-AH and ZL-MH are based on the ZL strain relief plate. By inserting the aluminium or brass grommets the ZL strain relief plate is free of fastening forces.


Strain relief, type ZL-AM / ZL-SW / ZL-C

The strain relief plates ZL-AM, ZL-SW and ZL-C are based on the ZL strain relief plate. The embedded brass discs hinder the cold flow deformation properties of the plastic under heavy and permanent vibration, thereby preventing the screwed connection from loosening by itself. Slot nuts and screws enable simple assembly on C-rails. Very rapid assembly Tidy, organised wiring routing Simple and effective straing relief with cable ties Microencapsulated precote thread pre-coating as additional safety component with Type ZL-AM / ZL-SW


Strain relief, type ZL-MF

The strain relief plate ZL-MF is based on the strain relief plate ZL. The preassembled feet enable simple, tool-free assembly on a 35mm top hat rail (EN 50022). The feet are made of galvanised steel plate. Quick and easy to assemble and disassemble without the need for tools. Orderly routing of the cable Simple and effective strain relief through cable ties


Strain relief, type ZLF

The strain relief plate ZLF is based on the strain relief plate ZL. The fastening clips that are used allow for simply mounting on c-rails with 10 mm slot and a plate thickness of max 2.0 mm. The premounted screw in the fastening clip allows the snap-on stand to be splayed and locked. Very quick assembly Orderly routing of the cable Simple and effective strain relief through cable ties


Strain relief, type ZL xx-AB

In conjunction with the ZL strain relief rail, the ZL-AB discharge plate is suitable for discharging interferences which may occur on cable sheaths. ZL strain relief not included in delivery. Please order separately.


Strain relief accessories

The DH spacer sleeve is required for stacking the ZL strain relief plate. This allows for cables to be stacked, thereby saving space. The ELB insert bushing can be laid into the strain relief plate type ZL. It prevents cold flow of the plastic at the fixing point during heavy strain or permanent movement.


Cable fixing plate, type KAF

The cable fixing plate KAF is suitable for simultaneously holding and relieving the strain of cables in the control cabinet. Mounting is performed on a 35 mm top hat rail (EN 50022; Niedax 2934;2936) or on a C-rail (Niedax 2970;2971). Installation is a simple snap-in process.


Cable fixing plate, type KAF/NI

The cable fixing plate KAF is suitable for simultaneously holding and relieving the strain of cables in the control cabinet. Mounted using Niedax model 2910 C-rail. Installation is a simple snap-in process. Additional securing through lock screw.


Cable fixing plate, type KAF/K

The cable fixing plate KAF/K-EMC consists of a plastic carrier with a fitted V2A discharge plate. Integrated clamps ensure quick and safe fastening, both on the top hat- or C-rail. The ground contact occurs through the lateral brackets. The use of two connecting points ensures a good discharge.


Cable fixing plate, type KAF/EK

The cable fixing plate KAF/K-EMC consists of a V2A plate for the direct discharge of any interference on the cable sheaths. Stripping the cable in the area of the cable fixing plate and fastening by means of cable ties ensures contact to the cable fixing plate. The ground contact is provided through a special screw stand for the 35 mm hat rail (EN50022). The KAF/EK is characterised by its extremely fast and easy assembly. Fits on 35 mm top hat rail (EN50022).


Cable fixing plate, type KAF/SF

The cable fixing plate KAF/SF is suitable for discharging interferences which may occur on cable sheaths. The ground contact is provided through a special snap-on stand for the 35 mm hat rail (EN50022). Stripping the cable in the area of the KAF/SF and clamping in the KAF/SF achieves a contact to the KAF/SF. The snap-on clip of the KAF/SF produces a low-resistance ground contact. The use of two connecting points ensures a good discharge regardless of the position of the cable on the KAF/SF. Fits on 35 mm top hat rail (EN50022) Simply snapped on


Cable fixing plate, type KAF/DC

The cable fixing plate KAF/DC is suitable for discharging interferences which may occur on cable sheaths. The ground connection occurs via the fixing screws. The version DC is only suitable for direct installation on a conductive background. Stripping the cable in the area of the cable fixing plate and fastening by means of cable ties ensures contact to the cable fixing plate. A low-resistance ground contact is achieved by mounting the KAF on the mounting plate. The use of two connecting points ensures a good discharge regardless of the position of the cable on the KAF.


Cable tie rail, type KBL

Quick and easy fitting of cables. Cable ties may be pushed on if a rail is already fitted.


Shielding clamp, type SK

The shielding clamp may be used where the shield of individual cables must be connected with earth potential. The shielding clamp can be either screwed down on the mounting plate (using the supplied screw) or snapped on to the 35 mm top hat rail (EN 50022) with a mounting foot. SK mounting foot not included in delivery. Please order separately.